Three Steps MTDC Providers Can Take to Reduce Energy Expenses by Panduit

MC Panduit Three Steps MTDC Can Take to Reduce Energy Expenses 1 400

June 16, 2022

 

It seems like IT leaders everywhere want the flexibility to run workloads wherever it makes the most sense; in an on-premises data center, public clouds, edge environments, and increasingly, in multi-tenant data centers (MTDCs).

Whether it’s to provide an optimized user experience for remote workers, or to take advantage of cutting-edge technologies, or to meet regional regulatory and compliance mandates, or simply to reduce management costs, MTDCs have become a critical part of highly distributed architectures. And while demand and occupancy are on the rise, so too are operating expenses for the MTDC providers who have assumed responsibility for the care and feeding of tenant applications and infrastructure.

While all MTDC facilities require power to function, savvy providers are focused on finding ways to become more energy-efficient in an effort to more effectively control – and hopefully reduce – costs.

Cooling, which alone accounts for nearly 37% of the overall data center power consumption and is the fastest rising data center operation expense, is a logical place to start.  Fortunately, from an infrastructure perspective, there are proven strategies for finding and fixing cooling inefficiencies, as well as optimizing cooling moving forward.

Here are three steps providers can take to get on the path to significant savings:

Step 1: Conduct a comprehensive facility assessment.

Racks house servers. Servers generate heat. Reducing heat, otherwise known as cooling, requires power. Sometimes lots of power. Therefore, it’s not uncommon to find half-empty racks inside data centers. Operators tap into power needed to regulate the temperature of a fully utilized rack.

A first step toward solving this kind of cooling conundrum is for data center design and efficiency experts to conduct an on-site assessment of the facility. Assessments can shine a light on myriad opportunities for reduce energy consumption of both passive and active data center equipment. For example, if those empty slots in racks are left uncovered, then cold air is being pushed into them for no good reason. Assessment can help identify where opportunities exist to close these openings with blanking panels to stop cooled air from passing through.

Assessments can also identify the need to implement cold aisle containment systems, which enclose these areas within a physical barrier. They separate supply and return airflow, and thus eliminate hot and cold air mixing. Some physical infrastructure providers – Panduit included – provide universal aisle containment solutions that are designed to work in mixed environments comprised of racks and equipment of different shapes and sizes provided by various vendors. While these systems are an up-front capital expenditure, they more than pay for themselves over time given that they can increase efficiency by as much as 40 percent.

Step 2: Implement sensors to instrument the environment.

Hotspots are local temperature variations that occur in a data center. They are detrimental to performance and can require significant power and cooling resources to correct them. Containment, as mentioned earlier in this post, is a proven remediation strategy. But hotspots can be hard to find. By installing wireless sensors, providers can monitor infrastructure health for these types of anomalies on a 24×7 basis.

At Panduit, we helped our customer WWT — who suspected that hotspots were causing them significant energy inefficiencies — find them, fix them, and immediately realize significant savings after instrumenting the environment with the Panduit SynapsenseTM wireless monitoring and cooling control solution. Comprised of wireless sensors and turnkey intelligent software, it provides quantifiable, actionable information that the WWT team uses to address multiple containment gaps and cooling inefficiencies. With SynapSense, they also learned they could reduce water temperatures of the chilled water plant and reduce fan speeds in certain areas. Overall, WWT realized a 50% annual savings on cooling costs and a 20% overall energy savings.

 

Watch this video to see Panduit’s SynapsenseTM wireless monitoring and cooling control solution in action

{videobox}qNNQMtr93To{/videobox}

 

Step 3: Leverage automation for ongoing optimization

Data centers are dynamic environments. In fact, now more than ever, tenants are running various types of workloads that each come with their own unique requirements for power and cooling. But once operators gain an understanding of all these workload needs, they can use this data to build benchmarks, and then leverage automation technologies to adjust air flow and cooling to meet tenant-specific – and workload-specific – requirements, on-demand.

CyrusOne, another Panduit customer, implemented the SynapSense SynapSoft® Software to continuously align cooling capacity with changing workloads. They use wireless sensors to measure and automatically adjust air temperature and pressure and fan speeds to optimize efficiencies without compromising performance.

For MTDC providers, having this ability to automatically dial in power and cooling based on workload needs goes a long way towards accurately calculating and charging tenants for power consumption. Historically, tenants have typically been charged flat fee based on the percentage of space they occupy. However, these days tenants are asking for more visibility into their actual power usage and demanding to be charged accordingly.

 

Source

 

Related Articles


Latest Articles

  • What Are Control Circuit Devices? Noark Electric Explains

    October 4, 2023 A Control Circuit Device regulates and manages the operation of an electrical circuit by turning on or off the circuit. The control device regulates or limits the condition within the circuit by controlling the voltage and current.  Examples of control circuit devices used are switches, solenoids, and relays. Noark is a reliable manufacturer of… Read More…

  • Transforming Manufacturing Processes with AMRs: Boosting Efficiency and Adaptability

    October 2, 2023 In today’s rapidly evolving business landscape, companies are constantly seeking innovative active solutions to optimize their manufacturing processes. One technology that has gained significant traction is the implementation of Autonomous Mobile Robots (AMRs). These versatile machines offer a wide range of benefits, empowering companies to transform their manufacturing operations and stay ahead… Read More…


Featured Article

Guillevin Strategies and Solutions: Enhancing the Customer Experience With a Comprehensive Website

Guillevin Strategies and Solutions: Enhancing the Customer Experience

In today’s customer-centric business climate, creative solutions are needed to provide customers with the seamless experience they’re looking for. By offering a comprehensive, easy-to-use website that meets the diverse needs of its customers, Guillevin meets this challenge. 

With the aim of building lasting relationships with its customers, the website serves as a platform that not only simplifies the purchasing process, but also contributes to the success of both short- and long-term partnerships.

Read More


Products

  • Noark Electric’s Definite Purpose Contactors Achieve UL Certification with A2L Refrigerant

    October 4, 2023 UL Certification aligns with HVAC industry’ mandate to reduce Global Warming Potential (GWP) and confirms that you can use these components in your system without further evaluation. Noark Electric’s Definite Purpose Contactors Noark Electric’s Definite Purpose Contactors are electrically operated switching devices designed for switching on and off heating, ventilation, and air conditioning (HVAC)… Read More…

  • New Endress+Hauser Pulsed Radar Level Sensor from AutomationDirect

    October 2, 2023 AutomationDirect has added the Endress+Hauser Micropilot FMR10 series pulsed radar liquid level sensor to their growing lineup of liquid level sensors. This new sensor is a downward facing, non-contact sensor that emits electromagnetic pulses and determines the level based on the time it takes for the pulses to be reflected back to… Read More…