Three Steps MTDC Providers Can Take to Reduce Energy Expenses by Panduit

MC Panduit Three Steps MTDC Can Take to Reduce Energy Expenses 1 400

June 16, 2022

 

It seems like IT leaders everywhere want the flexibility to run workloads wherever it makes the most sense; in an on-premises data center, public clouds, edge environments, and increasingly, in multi-tenant data centers (MTDCs).

Whether it’s to provide an optimized user experience for remote workers, or to take advantage of cutting-edge technologies, or to meet regional regulatory and compliance mandates, or simply to reduce management costs, MTDCs have become a critical part of highly distributed architectures. And while demand and occupancy are on the rise, so too are operating expenses for the MTDC providers who have assumed responsibility for the care and feeding of tenant applications and infrastructure.

While all MTDC facilities require power to function, savvy providers are focused on finding ways to become more energy-efficient in an effort to more effectively control – and hopefully reduce – costs.

Cooling, which alone accounts for nearly 37% of the overall data center power consumption and is the fastest rising data center operation expense, is a logical place to start.  Fortunately, from an infrastructure perspective, there are proven strategies for finding and fixing cooling inefficiencies, as well as optimizing cooling moving forward.

Here are three steps providers can take to get on the path to significant savings:

Step 1: Conduct a comprehensive facility assessment.

Racks house servers. Servers generate heat. Reducing heat, otherwise known as cooling, requires power. Sometimes lots of power. Therefore, it’s not uncommon to find half-empty racks inside data centers. Operators tap into power needed to regulate the temperature of a fully utilized rack.

A first step toward solving this kind of cooling conundrum is for data center design and efficiency experts to conduct an on-site assessment of the facility. Assessments can shine a light on myriad opportunities for reduce energy consumption of both passive and active data center equipment. For example, if those empty slots in racks are left uncovered, then cold air is being pushed into them for no good reason. Assessment can help identify where opportunities exist to close these openings with blanking panels to stop cooled air from passing through.

Assessments can also identify the need to implement cold aisle containment systems, which enclose these areas within a physical barrier. They separate supply and return airflow, and thus eliminate hot and cold air mixing. Some physical infrastructure providers – Panduit included – provide universal aisle containment solutions that are designed to work in mixed environments comprised of racks and equipment of different shapes and sizes provided by various vendors. While these systems are an up-front capital expenditure, they more than pay for themselves over time given that they can increase efficiency by as much as 40 percent.

Step 2: Implement sensors to instrument the environment.

Hotspots are local temperature variations that occur in a data center. They are detrimental to performance and can require significant power and cooling resources to correct them. Containment, as mentioned earlier in this post, is a proven remediation strategy. But hotspots can be hard to find. By installing wireless sensors, providers can monitor infrastructure health for these types of anomalies on a 24×7 basis.

At Panduit, we helped our customer WWT — who suspected that hotspots were causing them significant energy inefficiencies — find them, fix them, and immediately realize significant savings after instrumenting the environment with the Panduit SynapsenseTM wireless monitoring and cooling control solution. Comprised of wireless sensors and turnkey intelligent software, it provides quantifiable, actionable information that the WWT team uses to address multiple containment gaps and cooling inefficiencies. With SynapSense, they also learned they could reduce water temperatures of the chilled water plant and reduce fan speeds in certain areas. Overall, WWT realized a 50% annual savings on cooling costs and a 20% overall energy savings.

 

Watch this video to see Panduit’s SynapsenseTM wireless monitoring and cooling control solution in action

{videobox}qNNQMtr93To{/videobox}

 

Step 3: Leverage automation for ongoing optimization

Data centers are dynamic environments. In fact, now more than ever, tenants are running various types of workloads that each come with their own unique requirements for power and cooling. But once operators gain an understanding of all these workload needs, they can use this data to build benchmarks, and then leverage automation technologies to adjust air flow and cooling to meet tenant-specific – and workload-specific – requirements, on-demand.

CyrusOne, another Panduit customer, implemented the SynapSense SynapSoft® Software to continuously align cooling capacity with changing workloads. They use wireless sensors to measure and automatically adjust air temperature and pressure and fan speeds to optimize efficiencies without compromising performance.

For MTDC providers, having this ability to automatically dial in power and cooling based on workload needs goes a long way towards accurately calculating and charging tenants for power consumption. Historically, tenants have typically been charged flat fee based on the percentage of space they occupy. However, these days tenants are asking for more visibility into their actual power usage and demanding to be charged accordingly.

 

Source

 

Related Articles


Latest Articles

  • Building the Future of Smart Tool Manufacturing – Together

    Why now Is the time to join the AIMS ecosystem August 27, 2025 By Samuel Kirkpatrick, ANCA Senior Product Manager – AIMS The manufacturing industry is undergoing its most transformative shift in over a century. As smart automation, AI-driven production systems, and advanced robotics redefine what’s possible, manufacturers are seeking ways to scale efficiently, adapt… Read More…

  • Comparing maxon EC-i vs ECX Motors: Which One Fits Your Design?

    August 19, 2025 The choice between maxon’s EC-i and ECX motor series depends on whether the application prioritizes torque or speed, rugged durability or quick responsiveness, and high load-handling capability or low-inertia performance. Both maxon product lines use brushless DC motor technology but are engineered with distinct rotor architectures and performance envelopes. This comparison outlines… Read More…


Featured Article

Revolutionizing Material Movement with Autonomous Mobile Robots

Revolutionizing Material Movement with Autonomous Mobile Robots

In today’s fast-paced manufacturing and logistics industries, the need for efficient and flexible material movement solutions has never been greater. Traditional methods like conveyor systems, forklifts, and manual pushcarts have served us well, but they come with limitations.

That’s why Omron is thrilled to announce the launch of their game-changing MD Series of Autonomous Mobile Robots (AMRs). Read more


Products

  • Emergent Vision Technologies Announces All EROS 10GigE Camera Models Now Shipping

    August 27, 2025 Emergent Vision Technologies is announcing that all models of the groundbreaking EROS 10GigE camera series are now officially shipping. Originally launched in December 2024, Emergent Vision Technologies says EROS is the smallest, lowest power10GigE camera in the world. “Thirty-nine new cameras across color, mono, SWIR, polarized, and UV sensors are now available… Read More…

  • Remote Display Unit Type EXCRDU2 from Lovato Electric

    August 26, 2025 LOVATO Electric expands its range of accessories for soft starters and variable speed drives with the new EXCRDU2 remote display unit. It is compatible with LOVATO Electric soft starters ADXL series and ADXNP type, as well as variable speed drives VLB series, equipped with an optional RS485 port. Up to 32 devices can be connected to the same unit, even… Read More…